GENERAL CONDITIONS

General Conditions,

 

Storage conditions:

If the products are not stored in appropriate conditions, corrosion may occur on the parts. Since the packaging of the parts is Big Bag, the air inside cannot escape and may cause condensation. Therefore, even if the products are stored indoors, there is a possibility of rust or white rust. Especially in Tie Rod nuts, it is not technically possible to galvanize the threaded part. For this reason, there is a high probability of rusting from this area. However, none of these cause a technical weakness during the lifetime of the part. After receiving the products, the buyer is obliged to check the parts within 30 days at the latest. After this process, the buyer cannot make another complaint about the visual condition and / or quality  for the parts he bought. After 100% of the price of the products is paid, the ownership of the products passes to the buyer.

 

Reports:

The material report is sent when requested with each shipment. However, if a tensile or other special test is requested and a 3.1 test report in accordance with the EN10204 standard is requested, this must be notified in advance. Arı Ltd has the right to demand additional fees according to the content of the report.

 

Marking:

Although it varies from product to product, “CAX” lettering and/or “Arı Ltd logo” are present on the products. If it is possible to put a production date in production, there is a production date on all products. Otherwise it is available on the label on the packaging.

 

General use

Arı Ltd. is not responsible for any damages that may occur if all products listed or not listed here are used for purposes other than their intended use. The products must be stored in good conditions, used in accordance with the purpose (standards), should be visually checked before use and should not be used if there is any suspicious condition on the part. Arı Ltd reserves the right to change, add or subtract these terms at any time. These terms are published on our website at www.ariltd.com .

Tie Rod Nuts

  • Tie Rod nuts are tested according to DIN 18216 standards. The 2.1 tensile test report in accordance with the EN10204 standard is given as a standard.
  • However, if a 3.1 pull report in accordance with the EN10204 standard is requested, this must be specified in advance.
  • The ears of the nuts are not intended for hitting. Use Tie Rod to tighten or loosen nuts.
  • Do not use with a Tie Rod that is not in accordance with DIN 18216 and has not been approved by us.

Waterstop / Anchor Plates

  • Waterstops are tested according to DIN 18216 standard. The 2.1 tensile test report in accordance with the EN10204 standard is given as a standard.
  • However, if a 3.1 pull report in accordance with the EN10204 standard is requested, this must be specified in advance.
  • When installing the Waterstops, make sure that the Tie Rods are fully inserted (at least 5 teeth).
  • Do not use with a Tie Rod that is not in accordance with DIN 18216 and has not been approved by us.

Tie Rod

  • Do not use with accessories that do not comply with DIN 18216 standards and are not approved by us.
  • Tensile strength of the Tie Rod is 190 ±5% kN (Untreated, eg Galvanized, welded, etc.)

Formwork Panel Clamps

  • Panel Clamps must be mounted with a hammer of maximum 800 gr.
  • Do not oil or grease wedge-clamped joints.
  • The allowable tensile strength of each is different. Accordingly, the required amount of use should be calculated and used by you.
Conditions